Serviceline Industrial Sensors
Phone: 330-486-0001
Fax: 330-405-4710
Serviceline Explosion Protection
Phone: 330-486-0002
Fax: 330-963-5827

Power Supply PS1000-A6-24.5

PS1000-A6-24.5
  • 100 V AC to 240 V AC wide-range input
  • Output 24 V DC, 5 A, 120 W, 1-phase
  • Housing width 32 mm
  • Efficiency up to 94.3 %
  • Minimal inrush current surge
  • DC OK relay contact
  • Suitable for Zone 2/Div. 2 mounting
 in stock
172.00 USD
Netlist price. Your individual price will be calculated during checkout.
Unit Price 

Quantity

Free Shipping

Purchase on Account

Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.

Download the complete datasheet as a PDF:


Datasheet excerpt: Technical data of  PS1000-A6-24.5

Electrical specifications
Efficiency93.6 % at 120 V AC
94.3 % at 230 V AC
Power dissipation8.2 W at 120 V AC
7.3 W at 230 V AC
Input
Voltage range100 ... 240 V AC (-15 %/+10 %), 50 ... 60 Hz (±6 %)
110 ... 150 V DC (±20 %)
Current1.09 A at 120 V AC
0.6 A at 230 V AC
1.21 A at 110 V DC
for lower output currents see technical information
Inrush current5 A peak at 120 V AC and ambient temperature 40 °C (104 °F)
6 A peak at 230 V AC and ambient temperature 40 °C (104 °F)
or
ambient temperature 25 °C (77 °F)
Capacity factor0.98 at 120 V AC
0.91 at 230 V AC
Output
Rated voltage24 V DC
Voltage range24 ... 28 V DC
factory setting: 24.1 V
Rated current5 A
Current6 ... 5.1 A at ambient temperature < 45 °C (113 °F)
5 ... 4.3 A at ambient temperature 60 °C (140 °F)
3.8 ... 3.2 A at ambient temperature 70 °C (158 °F)
linear power derating see technical information
Power120 W
Ripplemax. 50 mV pp
Hold-up time35 ms at 120 V AC
35 ms at 230 V AC
Overload behaviorcontinuous current at output voltage > 13 V DC
Hiccup behaviour at output voltage < 13 V DC
Short-circuit currenttyp. 15 A for 12 ms or 3 A rms continuous current
Voltage limitationtyp. 30.5 V DC
max. 32 V DC
Fault indication output
Connectionterminals 13, 14
Output typerelay contact DC OK
- contact is closed if the output voltage is > 90 % of the adjusted output voltage
Contact loadingmax. 60 V DC/0.3 A ; 30 V DC/1 A ; 30 V AC/0.5 A resistive load
min. 1 mA at 5 V DC
Galvanic isolation
Input/OutputSELV/PELV
Indicators/settings
Display elementsLED green: status DC OK
- LED lights up if the output voltage is > 90 % of the adjusted output voltage
Control elementspotentiometer
Configurationsetting of the output voltage via potentiometer
Directive conformity
Electromagnetic compatibility
Directive 2014/30/EUIEC/EN 61000-6-1 , IEC/EN 61000-6-2 , IEC/EN 61000-6-3 , IEC/EN 61000-6-4 , IEC/EN 61000-3-2 ,
IEC/EN 61000-3-3
Low voltage
Directive 2014/35/EUEN 61010-1
RoHS
Directive 2011/65/EU (RoHS)IEC/EN 63000:2019
Conformity
Degree of protectionEN 60529
Shock resistanceEN 60068-2-27
Vibration resistanceEN 60068-2-6
Ambient conditions
Ambient temperature-25 ... 70 °C (-13 ... 158 °F) , see technical information
Storage temperature-40 ... 85 °C (-40 ... 185 °F)
Relative humidity5 ... 95 %, noncondensing
Shock resistance20 g , 11 ms or 30 g , 6 ms
Vibration resistance2 ... 17.8 Hz : ± 1.6 mm , 17.8 ... 500 Hz : 2 g
Mechanical specifications
Housing materialaluminum alloy , galvanized steel
Degree of protectionIP20
Connection
Input/Outputscrew terminals
conductor cross section: max. 6 mm2 (AWG 20-10)
cable diameter: max. 2.8 mm, wire end ferrules included
stripped insulation length: 7 mm
tightening torque: max. 1 Nm
Relay contact outputspring terminals with push-in connection technology
conductor cross section: max. 1.5 mm2 (AWG 24-16)
cable diameter: max. 1.6 mm, wire end ferrules included
stripped insulation length: 7 mm
Massapprox. 440 g  
Dimensions32 x 124 x 102 mm (W x H x D) , without DIN mounting rail
Height124 mm
Width32 mm
Depth102 mm
Mountingon 35 mm DIN mounting rail acc. to EN 60715:2001
Data for application in connection with hazardous areas
ATEX approval
ATEX certificateEPS 19 ATEX 1201 X
ATEX markingEx-Hexagon II 3G Ex ec nC II T4 Gc
Directive conformity
Directive 2014/34/EUEN 60079-0:2018 , EN 60079-7:2015+A1:2018 , EN 60079-15:2010
International approvals
UL approvalE350173 , E223176
IECEx approval
IECEx certificateIECEx EPS 20.0058X
IECEx markingEx ec nC IIC T4 Gc
StandardsIEC 60079-0:2017 , IEC 60079-7:2017 , IEC 60079-15:2017
General information
Supplementary informationObserve the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.

Classifications

SystemClasscode
ECLASS 13.019209090
ECLASS 12.019209290
ECLASS 11.019209290
ECLASS 10.0.119209290
ECLASS 9.019209290
ECLASS 8.019209290
ECLASS 5.127242392
ETIM 9.0EC002542
ETIM 8.0EC002542
ETIM 7.0EC002542
ETIM 6.0EC002542
ETIM 5.0EC002542
UNSPSC 12.139121004

Details: PS1000-A6-24.5

Function

The device is used to supply field devices with 24 V DC and 5 A.

The device has a power reserve of 20 % included, which may even be used continuously at temperatures up to +45 °C.

The output voltage can be adjusted via a potentiometer. The device status is indicated by an LED.

The device has a relay contact output for remote monitoring.

The device is mounted on a 35 mm DIN mounting rail according to EN 60715.

Informative Literature: PS1000-A6-24.5

Language Selection:
LiteratureLanguageFile TypeFile Size
BrochureUSAPDF2134 KB

Product Documentation: PS1000-A6-24.5

Language Selection:
Product informationLanguageFile TypeFile Size
Technical informationENGPDF2970 KB
Safety and Security Documentation
Instruction manual / BetriebsanleitungALLPDF243 KB
Instruction manual / BetriebsanleitungALLPDF348 KB

Design / Simulation: PS1000-A6-24.5

Language Selection:
CADLanguageFile TypeFile Size
CAD 3-D / CAD 3-DALLSTP3858 KB
CAD Portal / CAD PortalALLLINK---
CAE
CAE EPLAN macro EDZ / CAE EPLAN Makro EDZALLEDZ178 KB

Approvals: PS1000-A6-24.5

Language Selection:
CertificatesCertificate No.LanguageFile TypeFile Size
Bureau Veritas IECEx Certificate of ConformityIECEx EPS 20.0058XALLLINK---
Canada US ULUL E350173 (NRAD/NRAD7)ALLPDF83 KB
Europe Bureau Veritas ATEX Category 3 GEPS 19 ATEX 1 201XALLPDF786 KB
US CA ULCoC E223176 RptRef E223176-20070416ALLPDF444 KB
Declaration of Conformity
EU Declaration of Conformity (P+F) / EU-Konformitäterklärung (P+F)DOC-4784ALLPDF83 KB

Associated Products: PS1000-A6-24.5

Kit
1,621.00  USD
Netlist price. Your individual price will be calculated during checkout.

In stock

IIoT Starter Kit with IP20 EtherNet/IP Masterfa
1,621.00  USD

Contact Us

IIoT Starter Kit with IP67 EtherNet/IP Masterfa
1,621.00  USD

Contact Us

IIoT Starter Kit with IP20 PROFINET Master fa
IIoT Starter Kit with IP67 PROFINET Masterfa
Accessories

154.00  USD
Netlist price. Your individual price will be calculated during checkout.

In stock

Data carrierfa

436.00  USD
Netlist price. Your individual price will be calculated during checkout.

In stock

HF RFID read/write device with IO-Link in accordance with ISO 15693fa

Distance sensor, Medium design with versatile mounting options, Space-saving distance sensors in small standardized design, Multi Pixel Technology (MPT) - exact and precise signal evaluation, IO-Link interface for service and process datafa
Female cordset single-ended M12 straight L-coded, 5-pin, PUR cable grey, UL approvedfa
38.00  USD
Netlist price. Your individual price will be calculated during checkout.

In stock

Ethernet bus cable RJ45 to RJ45 PROFINET-coded, 4-pin, PUR cable green, Cat5e, shielded, drag chain suitablefa
EtherNet/IP IO-Link master with 8 inputs/outputsfa
Reduction factor 1, magnetic field resistant, Switching function: Normally open/closed (NO/NC) programmable, Output type: PNP, Rated operating distance: 4 mm (factory setting), Installation: flush, Output polarity: DC, Output type: 3-wire, Thread mold: M12, Construction type: Cylindrical, thread, Series: Cylindrical type, Operating voltage: 10 ... 30 V DC, Switching frequency: 0 ... 2000 Hz (switch point mode)
0 ... 125 Hz (window mode, switch point mode with stability alarm), Type of voltage: DCfa
156.00  USD
Netlist price. Your individual price will be calculated during checkout.

In stock

24 V DC to 28 V DC input, 2 inputs with 1 output, Output 24 V DC, 20 A, Housing width 32 mm, Built-in decoupling mosfets for 1+1 and N+1 redundancy, Automatic load sharing, Reverse input polarity protection, Easy wiring: distribution terminal for negative pole included, Redundancy status indicator, Suitable for Zone 2/Div. 2 mounting, Device type: device for DIN rail mounting, Function: Redundancy Module, Voltage range: 24 ... 28 V DCpa